EUDAMED: Registration, Obligations and Deadlines – What Applies Now
EUDAMED has been mandatory since 28 May 2026, and devices already on the market must be registered by 28 November 2026 at the latest. What applies now, which modules are still to come and how SRN, UDI and Basic UDI-DI fit together.
Nermin Duratović · Published · Updated · 6 min read
Status: 25 November 2026
EUDAMED, the European database on medical devices, was voluntary for years. Since 28 May 2026, the use of its first four modules has been mandatory. For manufacturers, authorised representatives and importers, this means that registrations required by the Medical Device Regulation (MDR) must be made in EUDAMED. For devices that were already on the market before, the deadline is 28 November 2026. From 29 November 2026, all devices must therefore be registered in EUDAMED. This article explains what applies now, what is still to come and where IT and regulatory affairs must work together.
What is EUDAMED?
EUDAMED is the European Commission's central IT system for medical devices and in vitro diagnostic devices. It is intended to create transparency and bring together information exchange between manufacturers, notified bodies, authorities and the public. The database consists of six modules:
| Module | Content | Status |
|---|---|---|
| Actor registration | Registration of manufacturers, authorised representatives, importers | mandatory since 28 May 2026 |
| UDI/Device registration | Devices with Basic UDI-DI, UDI-DI and device data | mandatory since 28 May 2026 |
| Notified bodies and certificates | Designations and issued certificates | mandatory since 28 May 2026 |
| Market surveillance | Exchange between authorities and the Commission | mandatory since 28 May 2026 (for authorities) |
| Vigilance and post-market surveillance | Incident reports, PSURs, trend reports | not yet mandatory |
| Clinical investigations and performance studies | Applications and reports | not yet mandatory |
The obligation was triggered by Commission Decision (EU) 2025/2371, published in the Official Journal on 27 November 2025, which declared the four modules functional. The basis for this gradual approach and its deadlines was created by Regulation (EU) 2024/1860, which amended Article 123(3) MDR. Up-to-date information is also published by the European Commission.
What applies now
| Date | What applies |
|---|---|
| since 28 May 2026 | Use of the four modules is mandatory. New devices must be registered before they are first placed on the market. |
| by 28 November 2026 | Deadline for devices placed on the market before 28 May 2026 that continue to be made available, including legacy devices under the old directives |
| from 29 November 2026 | All devices, including those already on the market, must be registered in EUDAMED. The data must be kept up to date whenever something changes. |
| by 28 May 2027 | Notified bodies enter the certificates they issued before 28 May 2026. |
| open | The vigilance/post-market surveillance and clinical investigation modules only become mandatory once the Commission announces their functionality in the Official Journal. The obligation then applies six months after publication. |
Anyone who missed the deadline for devices already on the market should complete the registration without further delay. A device that is on the market but not listed in EUDAMED will be noticed at the latest during an inspection by the authority or notified body.
Step 1: Actor registration and SRN
Every economic operator placing medical devices on the EU market first registers in the actor module. The competent national authority checks the information and issues a single registration number (SRN). Without a valid SRN, no further steps in EUDAMED are possible. Manufacturers based outside the EU register via their authorised representative.
Practical tip: set up roles and contact persons carefully. Decide beforehand who in the company may enter, review and approve data.
Step 2: Device registration with UDI
In the second step, devices are registered. Several identifiers work together:
- Basic UDI-DI: the key identifier for a device group with the same intended purpose, risk class and essential design and manufacturing characteristics. It links the device to the technical documentation, certificates and declaration of conformity.
- UDI-DI: the identifier of a specific device variant, for example a size or pack unit.
- UDI-PI: the production identifier, such as batch, serial number or expiry date. It appears on the label but is not registered in EUDAMED.
For legacy devices without a Basic UDI-DI, EUDAMED assigns its own identifiers: a EUDAMED DI instead of the Basic UDI-DI and a EUDAMED ID instead of the UDI-DI.
Master data is recorded for each device, including risk class, intended purpose, trade name, status (for example "on the market") and, where applicable, information on sterility, materials or components. For devices of class IIa and above, the notified body then links its certificate to the registered devices.
Step 3: Keeping data up to date
Registration is not the end. Changes to devices, status or contact persons must be updated. Since early 2025, an obligation under Article 10a MDR also applies: manufacturers must inform authorities, economic operators and health institutions if the supply of a device is interrupted or discontinued and this could result in serious harm. A device listed as "on the market" in EUDAMED that is no longer available can therefore become a problem.
EUDAMED as an IT project
For manufacturers with large portfolios, EUDAMED is above all a data task. Three routes are available:
| Route | Suitable for |
|---|---|
| Manual entry via the web interface | few devices |
| XML bulk upload | medium to large portfolios with occasional changes |
| Machine-to-machine interface (data exchange via an access point) | large portfolios, frequent changes, integration with ERP or PLM |
Typical pitfalls include master data spread across ERP, PLM and labelling systems, unclear responsibilities between IT and regulatory affairs, and poor data quality, such as different names for the same device. A data model with clear ownership and validation of the software used (see ISO 13485 certification) pay off twice here: for EUDAMED and for audits.
Checklist
- Check the SRN: is the company registered in EUDAMED and are all roles up to date?
- Map the portfolio: which devices are on the market? Which are MDR devices, which are legacy devices?
- Assign Basic UDI-DIs and UDI-DIs and align them with the technical documentation.
- Choose a route: manual, XML upload or machine-to-machine.
- Register devices already on the market (deadline: 28 November 2026), and new devices before they are first placed on the market.
- Define a maintenance process: who updates data in the event of changes, supply interruptions or market withdrawals?
- Involve the notified body so that certificates can be linked.
Conclusion
EUDAMED is not just a form but the new central data source for the European medical device market. Setting up master data, responsibilities and processes properly not only meets the registration obligation but also prepares the company for the modules still to come on vigilance and clinical investigations. Our article on MDR classification shows how a device's class determines the remaining obligations.
We help manufacturers set up EUDAMED registration, UDI structure and data processes at the interface of regulatory affairs and IT. Learn more about our MedTech consulting.
EUDAMED registration still open?
We review your actor data, UDI structure and device portfolio with you and define who maintains the data going forward.